Products

Browse PHYWE Quantum Physics products. Click any product for full details and to request a quote.

Modern Physics
12 mm lens for the camera in the Zeeman effect experiment
63300-04
12 mm lens for the camera in the Zeeman effect experiment
Accessory for cameras to widen the angle of exposure Screw-on objective with 12 mm lens To screw onto camera which is used in the Zeeman effect experi...
Modern Physics
Absorption material, lead
09029-01
Absorption material, lead
Absorption material for gamma and beta rays. Lead plates. Dimensions (cm): 1 x 5 x 10 (4 x); 0.5 x 5 x 10 (1 x).
Modern Physics
Alpha detector
09100-00
Alpha detector
Alpha detector, highly sensitive silicon surface barrier-layer detector. Measuring area: 50 mm2. Energy-resolution: 19 keV at 5.486 MeV. Thickness of ...
Modern Physics
Annular diaphragm with aluminium foil
09103-03
Annular diaphragm with aluminium foil
Annular diaphragm with aluminium foil for Rutherford experiment. Thickness of foil: 8 micrometer.
Modern Physics
Annular diaphragm with gold foil
09103-02
Annular diaphragm with gold foil
Annular diaphragm with gold foil for Rutherford experiment. Thickness of foil: 1.5 micrometer.
Modern Physics
Cadmium lamp for Zeeman effect
09050-20
Cadmium lamp for Zeeman effect
Vapour discharge lamp for the Zeeman effect Power supply for spectral lamps not included (art. no.: 13662-97) Can be used both for the variable magnet...
Modern Physics
Compact STM, Scanning Tunneling Microscope
09600-99
Compact STM, Scanning Tunneling Microscope
Easy-to-use scanning tunneling microscope for imaging and spectroscopy of conductive samples on an atomic or molecular scale. Suitable for a wide rang...
Modern Physics
Connect.cord f.Franck-H. tube
09105-50
Connect.cord f.Franck-H. tube
Connection cable with five poles and a diode plug as accessory for the Franck Hertz experiment (P2510315).
Modern Physics
Connecting cord for Franck-Hertz Hg-tube
09105-30
Connecting cord for Franck-Hertz Hg-tube
Connecting cord for Franck-Hertz Hg-tube. Connecting cord with diode plug and 5 labeled plugs connecting the operating device and the Franck-Hertz tub...
Modern Physics
Observation chamber of the fine beam tube
06959-01
Observation chamber of the fine beam tube
Observation chamber for covering the e/m experiment (Helmholtz coils and narrow beam tube). Parallax-free measuring of turning radii of electrons Meas...
Modern Physics
Electromagnet w/o pole shoes
06480-01
Electromagnet w/o pole shoes
(no description provided)
Modern Physics
Electron diffraction tube
06721-02
Electron diffraction tube
The electron diffraction tube enables the demonstration of the wave nature of electrons by observing interference patterns that become visible on the ...
Modern Physics
ESR extension set
09051-00
ESR extension set
For electron spin resonance apparatus (09051-93). Easy to use due to compact design With encapsulated sample substance (DPPH) and an unfilled referenc...
Modern Physics
ESR-NMR control panel (230 V, 50/60 Hz)
09051-11
ESR-NMR control panel (230 V, 50/60 Hz)
ESR / NMR control panel for the investigation of electron spin resonance (ESR) on the unpaired electron of DPPH (diphenyl-picryl-hydrazyl) molecules a...
Modern Physics
Experiment Set Quantum Cryptography
08675-00
Experiment Set Quantum Cryptography
The Quantum Cryptography Analogy Demonstration Kit contains components to model a data transmission setup using the BB84 encryption protocol. This enc...
Modern Physics
Fabry-Perot interferometer
09050-04
Fabry-Perot interferometer
(no description provided)
Modern Physics
Franck-Hertz control unit
09106-99
Franck-Hertz control unit
Compact operating unit for Franck-Hertz experiment to be used with Hg- and Ne-tubes. In 1913/14 James Franck and Gustav Hertz approved Bohr's mod...
Modern Physics
Franck-Hertz Hg-tube
09105-10
Franck-Hertz Hg-tube
The Hg tube on the plate is used for recording the Franck–Hertz curve. It is a replaceable high-vacuum tube filled with mercury, which evaporates when...
Modern Physics
Franck-Hertz Ne-tube in housing
09105-40
Franck-Hertz Ne-tube in housing
For recording the Franck–Hertz curve with up to 5 excitation collisions. Direct observation of visible light emission during de-excitation of excited ...
Modern Physics
Franck-Hertz oven for Hg-tube
09105-93
Franck-Hertz oven for Hg-tube
Franck-Hertz oven for Hg-tube Benefits: Metal housing with viewing. Adjustable heating. Bimetal switch for temperature stabilization. Holder for therm...
Modern Physics
Gamma detector
09101-00
Gamma detector
To detect gamma, beta and x-rays. Large volume thallium doped NaI-crystal in light-tight capsule, with photomultiplier with mumetal shielding mounted ...
Modern Physics
Geiger-Mueller counter tube, 15 mm (type B)
09005-00
Geiger-Mueller counter tube, 15 mm (type B)
Self-quenching halogen Geiger-Müller tube for detecting alpha, beta, and gamma radiation. Mounted in a metal cylinder with fixed 500 mm coaxial cable ...
Modern Physics
Gold (111) on sample support, for Compact Scanning Tunnellin Microscope
09607-00
Gold (111) on sample support, for Compact Scanning Tunnellin Microscope
(no description provided)
Modern Physics
Hall probe, tangential, protection cap
13610-02
Hall probe, tangential, protection cap
This Hall probe can be combined with the digital Teslameter or the measuring module of an interface. Due to the flat electrode particularly suitable f...
Modern Physics
Helmholtz coils, one pair
06960-06
Helmholtz coils, one pair
The Helmholtz coil pair generates a large-volume homogeneous magnetic field between the coils.It is used, among other applications, to investigate the...
Modern Physics
High vacuum pump assembly,compact
09059-99
High vacuum pump assembly,compact
Funktion and Applications Compact pumping station mounted on a mobile experimentation table with flexible vacuum feed through (bellow)on top of the ta...
Modern Physics
Holder for electron diffraction tube
06721-03
Holder for electron diffraction tube
Holder for electron diffraction tube Tube holder for the safe and easy acceptance of the electron tube. Connection: 4-mm-safety plugs Dimensions: 130m...
Modern Physics
holder for fine beam tube for 06960-06
06962-01
holder for fine beam tube for 06960-06
Holder for mounting the PHYWE fine beam tube inside the Helmholtz coils. Exact fit according to the dimensions of the Helmholtz spools. Material: PVC ...
Modern Physics
Holders for spectral tubes, 1 pair
06674-01
Holders for spectral tubes, 1 pair
Spectral tubes are secured with these holders to two insulating supports which are mounted on a stand.
Modern Physics
HOPG (Graphite) on sample support, for Compact Scanning Tunnling Microscope
09606-00
HOPG (Graphite) on sample support, for Compact Scanning Tunnling Microscope
(no description provided)
Modern Physics
Intrinsic conductivity Ge, carrier board
11807-01
Intrinsic conductivity Ge, carrier board
In connection with Hall effect module for determination of temperature dependent conductivity of undoped semiconductors. Heatable carrier board with u...
Modern Physics
Lead block, 200x100x50 mm
09029-11
Lead block, 200x100x50 mm
Coated lead block to shield from gamma radiation. Quantity: 1 piece. Dimensions (mm): 50 x 100 x 200. Mass: 11 kg.
Modern Physics
Lead brick with hole
09021-00
Lead brick with hole
Collimator for gamma rays. Lead brick with hole. Dimensions (mm): 50 x 100 x 200. Mass: 11 kg. Hole diameter: 15 mm.
Modern Physics
Magnetic System, variable, for beam height 150 mm
06327-02
Magnetic System, variable, for beam height 150 mm
(no description provided)
Modern Physics
09054-04
Matching transformer
Matching transformer in plastic housing as supply for Langmuir-Taylor detector. Primary: 0...16 V AC/0.6 A Secondary: 0...1.5 V AC/5 A Secondary drain...
Modern Physics
Millikan apparatus
09070-00
Millikan apparatus
The Millikan apparatus is used for the precise determination of the elementary charge of electrons.Using oil droplets suspended in an electric field, ...
Modern Physics
MoS2 on sample support, for STM
09608-00
MoS2 on sample support, for STM
(no description provided)
Modern Physics
NMR module
09051-01
NMR module
The NMR module is used with the ESR/NMR control unit to study nuclear magnetic resonance in glycerin, polystyrene, and Teflon. The equipment set consi...
Modern Physics
Operating unit for electron diffraction tube 230 V
06721-04
Operating unit for electron diffraction tube 230 V
High-voltage power supply for the safe operation of electron diffraction tubes. Ideal for laboratory use and demonstration experiments in teaching. It...
Modern Physics
Photocell for h-determination
06779-00
Photocell for h-determination
The photocell is used to investigate the photoelectric effect and for the experimental determination of Planck’s constant.The vacuum-sealed photocell ...
Modern Physics
PHYWE Electrometer amplifier
13621-00
PHYWE Electrometer amplifier
Operational amplifier with high resistance input for quasi-static voltage measurement respectively charge measurement, in fail-safe-plastic housing. S...
Modern Physics
PHYWE High voltage power supply with digital display, 10 kV DC: 0... ± 10 kV, 2 mA
13673-93
PHYWE High voltage power supply with digital display, 10 kV DC: 0... ± 10 kV, 2 mA
Universally applicable high-voltage source, suitable for all electrostatic experiments and experiments on radioactivity, as well as for operating spec...
Modern Physics
PHYWE Multichannel Analyser (MCA)
13727-99
PHYWE Multichannel Analyser (MCA)
The multichannel analyser is for analysing voltage pulses which are proportional to energy and for determining pulse rates and intensities in conjunct...
Modern Physics
Fine beam tube
06959-00
Fine beam tube
The fine beam tube allows the visualization of electron beams in an evacuated glass bulb, which fluoresce due to neon gas.It is mainly used in combina...
Modern Physics
PHYWE Universal measuring amplifier
13626-93
PHYWE Universal measuring amplifier
Universal measuring amplifier for amplification of AC and DC voltages. Suitable for lab courses. Input impedance of electrometer: > 10 (13) Ohm...
Modern Physics
Planck's "quantum of action" and external photoelectric effect
P2510511
Planck's "quantum of action" and external photoelectric effect
The photoelectric effect is one key experiment in the development of modern physics. White light from a filament lamp is filtered by a grating spectro...
Modern Physics
Polarization specimen, mica
08664-00
Polarization specimen, mica
To demonstrate polarization effects. Lambda/4 plate lamina at 550 nm Dimensions of plastic frame (mm): 50 x 50 x 6.8 Opening width: 10 mm
Modern Physics
Polarization specimen with mica λ/4 plate
08664-01
Polarization specimen with mica λ/4 plate
For demonstrating polarization effects. Technical Specification Type: Polaroid Retardation: 1/4 wavelength at 560 nm Useful diameter: 31 mm Calibratio...
Modern Physics
Pole piece, plane
06480-02
Pole piece, plane
To generate a homogeneous magnetic field, using 2 pieces together with electromagnet (06480.01). Length: 135 mm. Diameter: 39 mm.
Modern Physics
Pole pieces, drilled, conical
06480-03
Pole pieces, drilled, conical
(no description provided)
Modern Physics
Potassium ampoules, set of 6
09054-05
Potassium ampoules, set of 6
(no description provided)
Modern Physics
Pre-amplifier for alpha detector
09100-10
Pre-amplifier for alpha detector
Low noise amplifier. Operating voltage: +/- 12 V DC. Gain factor: approx. 4 terraV/As. Dimensions (mm): 127 x 65 x 112.
Modern Physics
Pt/Ir (80/20) wire, diameter 0.25mm, length 30 cm, for tunneling tip
09604-00
Pt/Ir (80/20) wire, diameter 0.25mm, length 30 cm, for tunneling tip
(no description provided)
Modern Physics
Quantum eraser with the Mach-Zehnder interferometer
P2220811
Quantum eraser with the Mach-Zehnder interferometer
A Mach-Zehnder-interferometer is illuminated with a laser beam. Circular interference fringes appear on the screens behind the interferometer. If pola...
Modern Physics
Radioactive source Am-241, 370 kBq
09090-11
Radioactive source Am-241, 370 kBq
Enclosed source for alpha radiation, suitable for experiments with ionisation chamber and spark counter as well as for Rutherford's experiment. S...
Modern Physics
Radioactive source Cs-137, 18.5 MBq
09096-20
Radioactive source Cs-137, 18.5 MBq
Encapsulated Beta(-)- and Gammaradiation source with storage container. Gamma-Energy 0,662 Half-life time 30,1 a , Handling permit required. Please th...
Modern Physics
Radioactive source Cs-137, 37 kBq
09096-01
Radioactive source Cs-137, 37 kBq
Enclosed gamma-emitter in a protective container. Adequate for energetic calibration of gamma-detectors. Isotope: Caesium 137 Half-live time: 30,1 a N...
Modern Physics
Rod, iron, d 25 mm, l 200 mm
09101-13
Rod, iron, d 25 mm, l 200 mm
Compton scattering object. Length: 200 mm. Diameter: 25 mm.
Modern Physics
Rotary table for heavy loads
02077-02
Rotary table for heavy loads
For rotatable mounting of an electromagnet. Inclination-adjustable metal base plate on adjustable feet. Lockable metal plate with ball bearings on top...
Modern Physics
Safety experiment cable for electron diffraction tube
06721-05
Safety experiment cable for electron diffraction tube
Set of safety experiment cables for electron diffraction tube 06721-02. Technical Specification Cable length: 75 cm. Cables in red, blue, and black: 4...
Modern Physics
09619-00
Sample support, 100 pcs, for STM and AFM
(no description provided)
Modern Physics
Screening cylinder for gamma detector
09101-11
Screening cylinder for gamma detector
Screening cylinder for gamma detector. Special lead material with very weak self-activity. On base plate with lateral slit diaphragm. Axial base hole:...
Modern Physics
Silver paint, for mounting samples on sample support
09605-00
Silver paint, for mounting samples on sample support
(no description provided)
Modern Physics
Source holder on fixing magnet
09202-00
Source holder on fixing magnet
For base plate or demonstration Physics board. For attaching radioactive sources. Painted metal holder with placement marks and magnet with sturdy non...
Modern Physics
Spectrum tube, helium
06668-01
Spectrum tube, helium
For determination of the line and band spectra of monoatomic and biatomic gases and of mercury vapour.Technical SpecificationGlass gas discharge tube ...
Modern Physics
Spectrum tube, Hg
06664-01
Spectrum tube, Hg
For determination of the line and band spectra of monoatomic and biatomic gases and of mercury vapour.Technical SpecificationGlass gas discharge tube ...
Modern Physics
Spectrum tube, hydrogen
06665-01
Spectrum tube, hydrogen
For determination of the line and band spectra of monoatomic and biatomic gases and of mercury vapour.Technical SpecificationGlass gas discharge tube ...
Modern Physics
Stern-Gerlach apparatus
09054-88
Stern-Gerlach apparatus
The Stern–Gerlach experiment demonstrates that the spatial orientation of angular momentum is quantized. More than 100 years have passed since the exp...
Modern Physics
XR 4.0 X-ray energy detector (XRED)
09058-36
XR 4.0 X-ray energy detector (XRED)
The X-ray energy detector (XRED) allows direct measurement of the energy of individual X-ray photons. Determine and analyze the complete X-ray energy ...
Modern Physics
Zeeman effect with a variable magnetic system
P2511010
Zeeman effect with a variable magnetic system
The Zeeman effect is the splitting up of the spectral lines of atoms within a magnetic field. The simplest is the splitting up of one spectral line in...
Modern Physics
Zeeman effect with electromagnet
P2511009
Zeeman effect with electromagnet
The Zeeman effect is the splitting up of the spectral lines of atoms within a magnetic field. The simplest is the splitting up of one spectral line in...

Ready to Equip Your Physics Lab?

Get a custom quote for your institution, curriculum alignment support, and grant assistance from AmSci's education specialists.

Contact AmSci Today →