X-Ray Physics equipment from the PHYWE Modern Physics range. 77 products, 110V/60Hz adapted for U.S. labs.
Supplied with software. Computer not provided.
Alignment of the detector and the rotation stage is very important to get optimal quality images of a CT scan.
X-ray sources produce a polychromatic spectrum which is altered when interacting with the sample. Due to this alteration, cupping effects in the reconstructed data of a CT scan.
Moseley's law describes the relationship between the energy of the Ka lines of characteristic X-ray spectra and the atomic number.
Spectra of X-rays from a copper anode are analyzed using different monocrystals and the results plotted graphically.
Characteristic X-rays of iron, supplied in the U.S. by American Scientific. Contact us for specifications.
Spectra of X-rays from a molybdenum anode are to be analyzed by means of different monocrystals and the results plotted graphically.
An X-ray tube with a tungsten anode generates X-radiation that is selected with the aid of a monocrystal as a function of the Bragg angle.
Chemicals for X-Ray-experiments, supplied in the U.S. by American Scientific. Contact us for specifications.
Photons of the molybdenum K α X-ray line are scattered at the quasi-free electrons of an acrylic glass cuboid.
Compton scattering is to be achieved by directing an X-ray beam against a piece of plastic. The portions of the scattered X-rays at various angles is to be measured with a counter tube.
The CT principle is demonstrated with the aid of simple objects. In the case of very simple targets, only a few images need to be taken in order to achieve a good result.
When a blood vessel model is irradiated with X-rays, the blood vessels themselves are not visible at first. It is only after the injection of a contrast medium that the blood vessels become visible.
The counter tube uses the ionising effect of high-energy radiation in order to measure the intensity of the radiation. The counter tube characteristics describe its working range, i.e.
(no description provided)
Debye-Scherrer diffraction measurements for the examination of the texture of rolled sheets, supplied in the U.S. by American Scientific. Contact us for specifications.
Debye-Scherrer diffraction patterns of powder samples with a hexagonal lattice structure, supplied in the U.S. by American Scientific. Contact us for specifications.
Debye-Scherrer diffraction patterns of powder samples with a tetragonal lattice structure, supplied in the U.S. by American Scientific. Contact us for specifications.
Polycrystalline powder samples, which crystallize in the three cubic Bravais types, simple, face-centered and body-centered, are irradiated with the radiation from a Roentgen tube with a copper anode.
A cubic crystalline powder sample is irradiated with the radiation from a X-ray tube with a copper anode.
Polycrystalline powder samples, which crystallize in the three cubic Bravais types, simple, face-centered and body-centered, are irradiated with the radiation from a Roentgen tube with a copper anode.
This experiment provides training in determining the length and position of an object based on an X-ray image. A metal pin that is embedded in a wooden block is used as the model.
Polychromatic X-rays impinge on a monocrystal under various glancing angles. The rays are reflected by the lattice planes of the monocrystal.
Diffraction measurements to determine the intensity of Debye-Scherrer reflexes using a cubic powder sample, supplied in the U.S. by American Scientific. Contact us for specifications.
X -ray spectra are recorded as a function of the anode voltage. The short wavelength limit of the bremsspectrum is used to determine the agreement with the Duane-Hunt displacement law, and to...
X-ray spectra of an X-ray tube are measured in an energy dispersive manner with a semiconductor detector and with various anode voltages.
Thin powder samples are subjected to polychromatic X-rays. The energy of the radiation that passes through the samples is analysed with the aid of a semiconductor detector and a multi-channel...
Energy Resolution Of The X Ray Energy Detector, supplied in the U.S. by American Scientific. Contact us for specifications.
The spectra of the X-rays that are reflected with various different orientations by NaCl monocrystals are analysed.
Depending on the type of CT scanner and the settings, the result of a CT scan of the same material can be different attenuation coefficient (grey-values).
Fluorescence radiation of the elements of a sample can cause fluorescence radiation inside the detector and its housing if the energy is sufficiently high.
As well as the outgoing radiation from a radioactive emitter is able to ionize air, so also X-radiation shows an ionizing effect. When air is penetrated by X-radiation, it is electrically conductive.
The polychromatic molybdenum X-ray spectrum is analyzed by means of a monocrystal. The energy of the characteristic lines is determined from the positions of the glancing angles at various orders of...
The polychromatic iron X-ray spectrum is to analyzed by means of a monocrystal. The energy of the characteristic lines is to be determined from the positions of the glancing angles for various orders...
Samples of various elements of different atomic numbers are irradiated with X-rays of a known spectral distribution. The energy of the transmitted intensities is analyzed using a monocrystal analyzer.
The X-rays that are generated by an X-ray tube are polychromatic. Numerous experiments (e.g.
The X-rays that are generated by an X-ray tube are polychromatic. Numerous experiments (e.g.
Optimization of the CT scan quality, supplied in the U.S. by American Scientific. Contact us for specifications.
(no description provided)
X-ray computed tomography consists of using X-rays that are converted to a digital signal by a detector and computational algorithms to calculate virtual sections through an object without the need...
With digital X-ray imaging, X-ray photons that interact with the detector are converted to a digital signal. This permits to record digital radiographies.
Principles Of Resolution And Detail Detectability, supplied in the U.S. by American Scientific. Contact us for specifications.
(no description provided)
X-rays penetrate objects that are impenetrable for visible light. The absorption depends on the thickness and type of the material.
The composition of various alloys is analysed with the aid of polychromatic X-rays. The energy of the characteristic fluorescence lines of the alloy constituents is analysed with the aid of a...
Various ore samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser.
Various powder samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser.
Qualitative X Ray Fluorescence Analysis Of Solutions, supplied in the U.S. by American Scientific. Contact us for specifications.
Various metal samples are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi channel analyser.
Various alloyed materials are subjected to polychromatic X-rays. The energy of the resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multichannel analyser.
Quantitative X Ray Fluorescence Analysis Of Solutions, supplied in the U.S. by American Scientific. Contact us for specifications.
An X-ray tube produces X-rays that cause a fluorescent screen to emit light. Objects that are located between the X-ray source and the fluorescent screen will be irradiated so that their inner...
Tess Expert Physics Handbook X Ray Experiments For Xr 4 0 Expert Unit, supplied in the U.S. by American Scientific. Contact us for specifications.
The polychromatic X-radiation from a copper anode is analyzed using a LiF monocrystal according to Bragg.
Various metal samples are subjected to polychromatic X-rays. The resulting fluorescence radiation is analysed with the aid of a semiconductor detector and a multi-channel analyser.
X-ray fluorescence spectroscopy-layer thickness determination, supplied in the U.S. by American Scientific. Contact us for specifications.
Laue diagrams are produced when monocrystals are irradiated with polychromatic X-rays. This method is primarily used for the determination of crystal symmetries and the orientation of crystals.
Laue diagrams are produced when monocrystals are irradiated with polychromatic X-rays. This method is primarily used for the determination of crystal symmetries and the orientation of crystals.
When polycrystalline samples are irradiated with X-rays a characteristic diffraction pattern results. These Debye-Scherrer reflections are photographed and then evaluated.
A polycrystalline zirconium foil is irradiated with X-rays. The resulting Debye-Scherrer reflections are photographed and then evaluated.
You cannot use the item without these accessories!
You cannot use the item without these accessories!
to fix the counter tube Type B 09005-00 on the optical Bench.
Upgrade set as an extension of the XR 4.0 X-ray unit.
Upgrade set as an extension of the XR4 unit.
Xr 4 0 X Ray Solid State Physics Upgrade Set, supplied in the U.S. by American Scientific. Contact us for specifications.
Upgrade set as an extension of the XRE 4.0 X-ray expert set (09110-88). This set is particularly suitable for the structural analysis of different types of samples in materials physics, chemical...
Aligned cupper (CU) X-ray tube in a sheet-steel housing with carrying handle for ready-to-use operation in the XR 4.0 expert unit.
Upgrade set as an extension of the XR 4.0 X-ray unit.
Teach the fundamentals of computed tomography (CT) with a set designed for laboratory courses and lectures in physics, medicine and materials science.
Accessory set to perform a wide range of CT experiments with the XR 4.0 computed tomography upgrade set.
Aligned molybdenum (Mo) X-ray tube in a sheet-steel housing with carrying handle for ready-to-use operation in the XR 4.0 expert unit.
Aligned iron (Fe) X-ray tube in a sheet-steel housing with carrying handle for ready-to-use operation in the XR 4.0 expert unit.
Aligned tungsten (W) X-ray tube in a sheet-steel housing with carrying handle for ready-to-use operation in the XR 4.0 expert unit.
Self-calibrating goniometer with two independently operating stepper motors for precise angular positioning of a sample and a detector, separately or in 2:1 coupling.
Upgrade set as an extension of the XR 4.0 X-ray expert set (09110-88). It is used for the characterisation of the radiation spectra of various different anode materials.
The complete set is designed for the safe execution of eight curriculum-compliant experiments in X-ray physics and X-ray imaging at school level.