Quantum Physics equipment from the PHYWE Modern Physics range. 73 products, 110V/60Hz adapted for U.S. labs.
12 mm lens for the camera in the Zeeman effect experiment, supplied in the U.S. by American Scientific. Contact us for specifications.
Absorption material for gamma and beta rays. Lead plates. Dimensions (cm): 1 x 5 x 10 (4 x); 0.5 x 5 x 10 (1 x).
Alpha detector, highly sensitive silicon surface barrier-layer detector.
Annular diaphragm with aluminium foil for Rutherford experiment. Thickness of foil: 8 micrometer.
Annular diaphragm with gold foil for Rutherford experiment. Thickness of foil: 1.5 micrometer.
Cadmium lamp for Zeeman effect, supplied in the U.S. by American Scientific. Contact us for specifications.
Easy-to-use scanning tunneling microscope for imaging and spectroscopy of conductive samples on an atomic or molecular scale.
Connection cable with five poles and a diode plug as accessory for the Franck Hertz experiment (P2510315).
Connecting cord for Franck-Hertz Hg-tube. Connecting cord with diode plug and 5 labeled plugs connecting the operating device and the Franck-Hertz tube.
Container For Nuclear Physics Experiments, supplied in the U.S. by American Scientific. Contact us for specifications.
Observation chamber for covering the e/m experiment (Helmholtz coils and narrow beam tube). Benefits Parallax-free measuring of turning radii of electrons Measuring of any turning radii of electrons...
(no description provided)
The electron diffraction tube enables the demonstration of the wave nature of electrons by observing interference patterns that become visible on the fluorescent screen after passing through a...
For electron spin resonance apparatus (09051-93).
You cannot use the item without these accessories!
The Quantum Cryptography Analogy Demonstration Kit contains components to model a data transmission setup using the BB84 encryption protocol.
(no description provided)
Compact operating unit for Franck-Hertz experiment to be used with Hg- and Ne-tubes.
The Hg tube on the plate is used for recording the Franck-Hertz curve. It is a replaceable high-vacuum tube filled with mercury, which evaporates when the tube is heated in a heating oven.
For recording the Franck-Hertz curve with up to 5 excitation collisions. Direct observation of visible light emission during de-excitation of excited neon atoms.
Franck-Hertz oven for Hg-tube, supplied in the U.S. by American Scientific. Contact us for specifications.
To detect gamma, beta and x-rays. Large volume thallium doped NaI-crystal in light-tight capsule, with photomultiplier with mumetal shielding mounted in holder with rod.
Self-quenching halogen Geiger-Müller tube for detecting alpha, beta, and gamma radiation.
(no description provided)
This Hall probe can be combined with the digital Teslameter or the measuring module of an interface. Due to the flat electrode particularly suitable for measuring in narrow air gaps and in longcoils.
The Helmholtz coil pair generates a large-volume homogeneous magnetic field between the coils.
Compact pumping station mounted on a mobile experimentation table with flexible vacuum feed through (bellow)on top of the table desk.
Tube holder for the safe and easy acceptance of the electron tube.
Holder for mounting the PHYWE fine beam tube inside the Helmholtz coils.
Spectral tubes are secured with these holders to two insulating supports which are mounted on a stand.
(no description provided)
In connection with Hall effect module for determination of temperature dependent conductivity of undoped semiconductors.
Coated lead block to shield from gamma radiation. Quantity: 1 piece. Dimensions (mm): 50 x 100 x 200. Mass: 11 kg.
Collimator for gamma rays. Lead brick with hole. Dimensions (mm): 50 x 100 x 200. Mass: 11 kg. Hole diameter: 15 mm.
(no description provided)
Matching transformer in plastic housing as supply for Langmuir-Taylor detector.
The Millikan apparatus is used for the precise determination of the elementary charge of electrons.
(no description provided)
The NMR module is used with the ESR/NMR control unit to study nuclear magnetic resonance in glycerin, polystyrene, and Teflon.
High-voltage power supply for the safe operation of electron diffraction tubes. Ideal for laboratory use and demonstration experiments in teaching.
The photocell is used to investigate the photoelectric effect and for the experimental determination of Planck’s constant.
Operational amplifier with high resistance input for quasi-static voltage measurement respectively charge measurement, in fail-safe-plastic housing.
Universally applicable high-voltage source, suitable for all electrostatic experiments and experiments on radioactivity, as well as for operating special tubes and other gas discharge tubes.
The multichannel analyser is for analysing voltage pulses which are proportional to energy and for determining pulse rates and intensities in conjunction with an X-ray detector, alpha detector or...
The fine beam tube allows the visualization of electron beams in an evacuated glass bulb, which fluoresce due to neon gas.
Universal measuring amplifier for amplification of AC and DC voltages. Suitable for lab courses.
The photoelectric effect is one key experiment in the development of modern physics. White light from a filament lamp is filtered by a grating spectrometer and illuminates a photocell.
Polarization specimen, mica, supplied in the U.S. by American Scientific. Contact us for specifications.
Polarization specimen with mica λ/4 plate, supplied in the U.S. by American Scientific. Contact us for specifications.
To generate a homogeneous magnetic field, using 2 pieces together with electromagnet (06480.01). Length: 135 mm. Diameter: 39 mm.
(no description provided)
(no description provided)
Low noise amplifier. Operating voltage: +/- 12 V DC. Gain factor: approx. 4 terraV/As. Dimensions (mm): 127 x 65 x 112.
(no description provided)
Quantum eraser with the Mach-Zehnder interferometer, supplied in the U.S. by American Scientific. Contact us for specifications.
Enclosed source for alpha radiation, suitable for experiments with ionisation chamber and spark counter as well as for Rutherford's experiment. Supplied in metallic protective container.
Encapsulated Beta(-)- and Gammaradiation source with storage container. Gamma-Energy 0,662 Half-life time 30,1 a , Handling permit required.
Enclosed gamma-emitter in a protective container. Adequate for energetic calibration of gamma-detectors.
Compton scattering object. Length: 200 mm. Diameter: 25 mm.
For rotatable mounting of an electromagnet.
Set of safety experiment cables for electron diffraction tube 06721-02.
Contact us for full product details and specifications.
Screening cylinder for gamma detector, supplied in the U.S. by American Scientific. Contact us for specifications.
(no description provided)
For base plate or demonstration Physics board. For attaching radioactive sources. Painted metal holder with placement marks and magnet with sturdy non-slipfoil. Adhesive force: 10 N.
Spectrum tube, helium, supplied in the U.S. by American Scientific. Contact us for specifications.
For determination of the line and band spectra of monoatomic and biatomic gases and of mercury vapour.
For determination of the line and band spectra of monoatomic and biatomic gases and of mercury vapour.
The Stern-Gerlach experiment demonstrates that the spatial orientation of angular momentum is quantized.
Student Set General Chemistry Digital Tess Advanced Chemistry, supplied in the U.S. by American Scientific. Contact us for specifications.
The X-ray energy detector (XRED) allows direct measurement of the energy of individual X-ray photons.
Zeeman effect with a variable magnetic system, supplied in the U.S. by American Scientific. Contact us for specifications.
Software included. Computer not provided.